Three phase 1000kw open style diesel generator set
Standard Features:1.All generator set comply with international design and quality standards, such as ISO8528(GB/T2820-97), ISO3046,
BS.EN60034, BS5000, IEC34-1, GB755, VDE0530, CSA22-2, AS1359, and so on.
2.Engine and alternator coupled with the compact base of structure steel, equipped with exhaust silencer and radiator.
3.AVESPEED designed controller IS900 and multiple circuit breaker as a standard configuration for single unit.
4.One year limited warranty covers all systems and components.
BS.EN60034, BS5000, IEC34-1, GB755, VDE0530, CSA22-2, AS1359, and so on.
2.Engine and alternator coupled with the compact base of structure steel, equipped with exhaust silencer and radiator.
3.AVESPEED designed controller IS900 and multiple circuit breaker as a standard configuration for single unit.
4.One year limited warranty covers all systems and components.
>>Prime power(Unlimited Time Running)
This rating is applicable for supplying electrical power in lieu of commercially purchased power.
Variable load should not exceed a 70% average of the prime power rating during any operating period of 250 hours,
The total operating time at 100% prime power shall not exceed 500 hours per year and this model can supply 10% over-load power for 1 hour in 12 hours.
>>Standby power
There rating should be applied where reliable utility power is available.
A standby rated engine should be sized for a maximum of an 80% average load factor and 200 hours of operation per year.
No overload capability is available for this rating.
NOTE 1:
All data is based on:
1. Engine operating with fuel system, water pump, lubricating oil pump, air cleaner and exhaust silencer;
not included are battery charging alternator, fan, and optional driven components.
2. Engine operating with fuel corresponding to grade No. 2-D per ASTM D975.
3. ISO 3046, Part 1, Standard Reference Conditions of:
Barometric Pressure: 100 kPa (29.53 in Hg)
Air Temperature : 25 degree centigrade;
Altitude:110 m (361 ft); Relative Humidity:30%;
Air Intake Restriction: 254 mm H2O (10 in H2 O);Exhaust Restriction : 51 mm Hg (2 in Hg).
4. Backed by worldwide service network.
N/A : Not Available;
TBD: To Be Determined;
NOTE 2:
1. Alternators meet the requirement of BS EN 60034 and the relevant section of other international standards such as BS5000,
VDE 0530, NEMA MG1-32, IEC34, CSAC22.2-100, As1359,
and other standards and certifications can be considered on request.
2. Brushless alternator with brushless pilot exciter for excellent load response.
3. Backed by worldwide service network.
This rating is applicable for supplying electrical power in lieu of commercially purchased power.
Variable load should not exceed a 70% average of the prime power rating during any operating period of 250 hours,
The total operating time at 100% prime power shall not exceed 500 hours per year and this model can supply 10% over-load power for 1 hour in 12 hours.
>>Standby power
There rating should be applied where reliable utility power is available.
A standby rated engine should be sized for a maximum of an 80% average load factor and 200 hours of operation per year.
No overload capability is available for this rating.
NOTE 1:
All data is based on:
1. Engine operating with fuel system, water pump, lubricating oil pump, air cleaner and exhaust silencer;
not included are battery charging alternator, fan, and optional driven components.
2. Engine operating with fuel corresponding to grade No. 2-D per ASTM D975.
3. ISO 3046, Part 1, Standard Reference Conditions of:
Barometric Pressure: 100 kPa (29.53 in Hg)
Air Temperature : 25 degree centigrade;
Altitude:110 m (361 ft); Relative Humidity:30%;
Air Intake Restriction: 254 mm H2O (10 in H2 O);Exhaust Restriction : 51 mm Hg (2 in Hg).
4. Backed by worldwide service network.
N/A : Not Available;
TBD: To Be Determined;
NOTE 2:
1. Alternators meet the requirement of BS EN 60034 and the relevant section of other international standards such as BS5000,
VDE 0530, NEMA MG1-32, IEC34, CSAC22.2-100, As1359,
and other standards and certifications can be considered on request.
2. Brushless alternator with brushless pilot exciter for excellent load response.
3. Backed by worldwide service network.
Specifications of Genset
Model Specification | KTA50-G3 | |
BASIC TECHNICAL DATA | ||
Engine type | 4-cycle,T=turbocharged, -/A=- /water-air after-cooled | |
Cylinder arrangement | 16cylinders,Vee 60° | |
Bore and stroke(mm) | 159×159 | |
Compression ratio | 13.9:1 | |
Displacement(L) | 50.3 | |
Estimated total weight (dry)(kg) | 4858 | |
Engine rated speed(rpm) | 1500 | |
Prime power(kW).gross | 1097 | |
Standby power(kW).gross | 1227 | |
EXHAUST SYSTEM | ||
Air intake flow(L/sec).rate | 1546 | |
Exhaust flow ( L/sec ).rate | 4231 | |
Exhaust temperature.rate | 583 | |
Max. back pressure(kpa) | 10 | |
Diameter of exhaust pipe (mm) | TBD | |
COOLING SYSTEM | ||
Coolant capacity(only engine)(L) | 161 | |
FUEL CONSUMPTION | ||
Standby power(L/h) | 282 | |
100% prime power(L/h) | 254 | |
75% prime power(L/h) | 195 | |
50% prime power(L/h) | 138 | |
LUBRICATION SYSTEM | ||
Oil pan capacity(L) | 177 | |
ELECTRIC SYSTEM | ||
Governor type | Electronic | |
Starter motor | 24V | |
Battery charging system | 35A |