PRODUCT DESCRIPTIONS
1.Power by Engine
2.With Stamford / Leroy Somer / Marathon Alternator
3. With CHINT / ABB MCCB & Electronic Components
4. Electric Start with Battery
5. Base Integrated Fuel Tank
6. ATS, Deepsea / ComAp / Smartgen Controller
7. Comply with ISO9001/CE
8. After-sale Services



1. Generator diesel High-quality steel are thickness canopy -- 2MM to 6MM2.With Stamford / Leroy Somer / Marathon Alternator
3. With CHINT / ABB MCCB & Electronic Components
4. Electric Start with Battery
5. Base Integrated Fuel Tank
6. ATS, Deepsea / ComAp / Smartgen Controller
7. Comply with ISO9001/CE
8. After-sale Services



Generator/Genset Model | Prime Power | Standby Power | Engine | Fuel Consumption | Cylinder No. | Displacement | Bore X Stroke | ||
KW | KVA | KW | KVA | (g/kwh) | (L ) | (mm) | |||
ST-C30GF | 20 | 25 | 24 | 30 | 4B3.9-G | ≤229 | 4 | 3.9 | 102*120 |
ST-C35GF | 24 | 30 | 28 | 35 | 4BT3.9-G | ≤214 | 4 | 3.9 | 102*120 |
ST-C56GF | 40 | 50 | 45 | 56 | 4BTA3.9-G | ≤215 | 4 | 3.92 | 102*120 |
ST-C63GF | 45 | 56 | 50 | 63 | 4BTA3.9-G | ≤215 | 4 | 3.92 | 102*120 |
ST-C70GF | 50 | 63 | 56 | 70 | 6BT5.9G1 | ≤215 | 6 | 5.88 | 102*120 |
ST-C106GF | 78 | 98 | 85 | 106 | 6BT5.9G | ≤215 | 6 | 5.88 | 102*120 |
ST-C125GF | 90 | 113 | 100 | 125 | 6BT5.9G2 | ≤215 | 6 | 5.88 | 102*120 |
ST-C150GF | 104 | 130 | 120 | 150 | 6BT5.9G2 | ≤215 | 6 | 5.88 | 102*120 |
ST-C165GF | 120 | 150 | 132 | 165 | 6CTA8.3-G2 | ≤210 | 6 | 8.3 | 114*135 |
ST-C200GF | 140 | 175 | 160 | 200 | 6CTA8.3-G2 | ≤210 | 6 | 8.3 | 114*135 |
ST-C225GF | 160 | 200 | 180 | 225 | 6CTAA8.3-G2 | ≤210 | 6 | 8.3 | 114*135 |
ST-C275GF | 200 | 250 | 220 | 275 | 6LTAA8.9-G2 | ≤210 | 6 | 8.3 | 114*135 |
ST-C313GF | 220 | 275 | 250 | 313 | NTA855-G1A | ≤206 | 6 | 14 | 140*152 |
ST-C350GF | 250 | 313 | 275 | 350 | NTA855-G2 | ≤207 | 6 | 14 | 140*152 |
ST-C400GF | 280 | 350 | 310 | 400 | NTA855-G4 | ≤208 | 6 | 14 | 140*152 |
ST-C413GF | 300 | 375 | 330 | 413 | NTAA855-G7 | ≤206 | 6 | 14 | 140*152 |
ST-C450GF | 320 | 400 | 360 | 450 | NTAA855-G7A | ≤206 | 6 | 14 | 140*152 |
ST-C500GF | 360 | 450 | 400 | 500 | KTA19-G3 | ≤203 | 6 | 18.9 | 159*159 |
ST-C550GF | 400 | 500 | 440 | 550 | KTA19-G4 | ≤203 | 6 | 18.9 | 159*159 |
ST-C605GF | 440 | 550 | 484 | 605 | KTAA19-G6 | ≤204 | 6 | 18.9 | 159*159 |
ST-C625GF | 450 | 563 | 500 | 625 | KTAA19-G7 | ≤204 | 6 | 18.9 | 159*159 |
ST-C700GF | 500 | 625 | 560 | 700 | KTA38-G | ≤206 | 12 | 37.8 | 159*159 |
ST-C712GF | 520 | 650 | 570 | 712 | QSK19-G3 | ≤206 | 6 | 19 | 159*159 |
ST-C800GF | 580 | 720 | 640 | 800 | KTA38-GA | ≤209 | 12 | 37.8 | 159*159 |
ST-C825GF | 600 | 750 | 660 | 825 | KTA38-G2 | ≤210 | 12 | 37.8 | 159*159 |
ST-C888GF | 640 | 800 | 710 | 888 | KTA38-G2B | ≤210 | 12 | 37.8 | 159*159 |
ST-C975GF | 720 | 900 | 780 | 975 | KTA38-G2A | ≤210 | 12 | 37.8 | 159*159 |
ST-C1075GF | 800 | 1000 | 860 | 1075 | KTA38-G5 | ≤202 | 12 | 37.8 | 159*159 |
ST-C1375GF | 1000 | 1250 | 1100 | 1375 | KTA50-G3 | ≤215 | 16 | 50.3 | 159*159 |
ST-C1375GF | 1100 | 1375 | 1310 | 1650 | KTA50-G8 | ≤215 | 16 | 50.3 | 159*159 |
ST-C1650GF | 1200 | 1500 | 1340 | 1675 | KTA50-GS8 | ≤215 | 16 | 50.3 | 159*159 |
ST-C1675GF | 1350 | 1688 | 1500 | 1875 | QSK60-G3 | ≤215 | 16 | 60 | 159*159 |
ST-C1875GF | 1500 | 1875 | 1650 | 2063 | QSK60-G3 | ≤215 | 16 | 60 | 159*190 |
ST-C2063GF | 1600 | 2000 | 1800 | 2250 | QSK60-G4 | ≤215 | 16 | 60 | 159*190 |
Details & Advantages
2. Generator diesel high-density sound-absorbing material -- sound insulation, fireproofing
3. Generator diesel 12V/ 24V DC battery with charger, battery connects a wire
4. Generator diesel 10-12 hours fuel tank with fuel indicator, long time for working.
5. Genset High protects the class control box and power output box. IP55, Waterproof, Electric leakage
protect, Breaker
6.A new design of turn-back type for air inflow & air outlet which can reduce the noise and improve engine
efficiency.
7.Generator diesel Beautiful & practicably design, a Bottom hole for forklift, Water outlet & oil outlet for easy
maintenance
8. Double open door on both sides of the Gensets.Spacious doors can check for every part of the engine
and alternator.
Main Engine Brand Introduction | ||||||
Generator Brand | Generator Power(KW) | Generator Power(Kva) | Consumption Diesel(l/hr) | Voltage(V) | Frequency(HZ) | Speed(RPM) |
16-1560 | 20-1950 | 5.7-339.9 | 230/400 | 50/60 | 1500/1800 | |
8-2000 | 10-2250 | 3-529 | 230/400 | 50/60 | 1500/1800 | |
Volvo Series | 68-544 | 85-680 | 16-133 | 230/400 | 50/60 | 1500/1800 |
MTU serirs | 520-2600 | 650-3250 | 126.5-623.8 | 230/400 | 50/60 | 1500/1800 |
Mitsubishi Series | 480-2000 | 600-2500 | 125-525 | 230/400 | 50/60 | 1500/1800 |
Yangdong series | 7.2-48 | 9-65 | <240 | 230/400 | 50/60 | 1500/1800 |
SDEC series | 48-800 | 60-1000 | 195-225 | 230/400 | 50/60 | 1500/1800 |
Other series ( Container type / Marine series etc. ) |


Packing&Delivery
1) Wrap the generator set by stretch film, and put some drying agent.
2) Adopt a steel plate or wood rib to make it stronger, can afford rough handling.
3) Design for forklift truck working in 4 directions. Fastened by 8cm length galvanized nail.
4) Load the case into a container by forklift trucks.