1. Smart canopy design as Denyo type.
2. Spare parts same as Perkins, can be used on Perkins engine
3. Spare Parts free within 1 year ganrantee.
Options for diesel geneator:
1) AMF + ATS
2) controller
3) silent canopy
4) trailer
LOVOL ENGINE:

CE and ISO approved diesel generator set powered by Lovol engine from20KW to 100KW
Product DescriptionGenset parameter
Model | Engine | Alternator | Controller with Panel | Output | |||
400/230v-50Hz/1500rpm | |||||||
KVA | KW | ||||||
PRP | ESP | PRP | ESP | ||||
GF2/3L-24 | 1003G | 184G-25 | DSE7320 | 28.8 | 32 | 23 | 25.6 |
GF2/3L-40 | 1003TG | 224D-40 | DSE7320 | 45.9 | 51 | 36 | 40.8 |
GF2/3L-35 | 1004G | 224C-35 | DSE7320 | 39.6 | 44 | 31 | 35.2 |
GF2/3L-50 | 1004TG | 224E-48 | DSE7320 | 69.3 | 77 | 55 | 61.6 |
GF2/3L-80 | 1006TG1A | 274C-80 | DSE7320 | 99 | 110 | 79 | 88 |
GF2/3-100 | 1006TAG1A | 274D-96 | GU620A | 126 | 140 | 100 | 112 |
GF2/3-130 | 1106C-P6TAG3 | 274F-125 | GU620A | 164 | 182 | 131 | 146 |
Engine parameter
Model Number: 1003 & 1004 & 1006 | |||||||||
Lovol 1000 Series Generating Diesel Engines | |||||||||
The engines for gensets application belong to Lovol 1000 series. The engines become smaller and lighter with technical innovation, while at the same time they maintain the advantage such as strong power, environmental friendiness, good reliability and convenient maintenance. These engines can be equipped with imported or domestic electronic governors, and can be applied to 28KW to 134KW gensets,. The rated speed includes 1500r/min and 1800r/min. therefore various demands from customers can be met. | |||||||||
Item | 1003G | 1003TG | 1004G | 1004TG | 1006TG1A | 1006TG2A | 1006TAG | ||
Cylinder number | 3 | 3 | 4 | 4 | 6 | 6 | 6 | ||
Cylinder arrangement | In line | In line | In line | In line | In line | In line | In line | ||
Induction system | Naturally aspirated | Turbocharged | Naturally aspirated | Turbocharged | Turbocharged | Turbocharged | Turbocharged air-to-air charge cooled | ||
Borexstroke(mm) | 100x127 | 100x127 | 100x127 | 100x127 | 100x127 | 100x127 | 100x127 | ||
Displacement(L) | 3 | 3 | 3.99 | 3.99 | 5.99 | 5.99 | 5.99 | ||
Compression ratio | 16.5 | 17.5 | 16.5 | 17.5 | 17.5 | 17.5 | 17.5 | ||
Lubricating system capacity(L) | 7.48-8.68 | 7.48-8.68 | 8.1 | 8.5 | 16.1 | 16.1 | 19 | ||
Firing order | 1,2,3 | 1,2,3 | 1,3,4,2 | 1,3,4,2 | 1,5,3,6,2,4 | 1,5,3,6,2,4 | 1,5,3,6,2,4 | ||
Diesel engine | (kW/1500rpm) | 30 | 44 | 44 | 72.3 | 92.7 | 102 | 134 | |
Max. power/speed | (kW/1800rpm) | 36 | 55 | 48 | 83.2 | 107.3 | 119.2 | 147 | |
Diesel engine | (kW/1500rpm) | 28 | 40 | 40 | 65.7 | 84.3 | 92.3 | 121 | |
continuous power /speed | (kW/1800rpm) | 33 | 50 | 44 | 75.6 | 97.6 | 108.4 | 134 | |
Corresponding Leroy-Somer alternator type | LSA42.2 M7 | LSA43.2 S15 | LSG26.2 | LSG29.2 | LSG31.2 | LSG32.2 | LSG34.2 | ||
Genset power | Prime(Continuous) | 27 | 40 | 34 | 56 | 71 | 78 | 102 | |
(kW/1500rpm) | Standby(Maximum) | 30 | 44 | 38 | 61 | 80 | 86 | 112 | |
Genset power | Prime(Continuous) | 27 | 40 | 37 | 64 | 83 | 92 | 113 | |
(kW/1800rpm) | Standby(Maximum) | 30 | 44 | 41 | 70 | 91 | 101 | 124 | |
Min. fuel consumption(g/kWh) | <=210 | <=205 | <=210 | <=205 | <=205 | <=205 | <=205 | ||
Average sound dB(A) | 94 | 94 | 92 | 93 | 94 | 94 | 95 | ||
Governing | Mechanical governing | <=5% | <=5% | <=5% | <=5% | <=5% | <=5% | <=5% | |
Electronic governing | <=1% | <=1% | <=1% | <=1% | <=1% | <=1% | <=1% | ||
Emission | Tier1 | Tier1/Tier2 | Tier1 | Tier1/Tier2 | Tier1/Tier2 | Tier1/Tier2 | Tier1/Tier2 | ||
Area of heat dissipation | 17 | 19 | 19.7 | 26.94 | 33.27 | 33.27 | 25.86 (Radiator) | ||
33.27 (InterCooler) | |||||||||
Weight(kg) | 410 | 415 | 540 | 550 | 710 | 710 | 730 | ||
Electric system | Standard configuration 24V, optional 12V | ||||||||
Overall dimensions (mm)AxBxC | 1012x715x940 | 1012x715x940 | 1253x706x946 | 1253x706x946 | 1484x740x1107 | 1484x740x1107 | 1600x800x1064 | ||
Model | 1003G1A | 1003TG1A | 1004TG1A | 1006TG3A | 1006TAG1A | ||||
Cylinder number | 3 | 3 | 4 | 6 | 6 | ||||
Genset Power (KW) | 20 | 30 | 45 | 75 | 90 | ||||
Rated Power (KW) | 1500r/min | 26 | 38 | 52 | 86 | 108 | |||
1800r/min | 28 | 42 | 58 | 100 | 121 | ||||
Max. Power (KW) | 1500r/min | 28.6 | 42 | 57 | 94.6 | 119 | |||
1800r/min | 30.8 | 46 | 64 | 110 | 133 | ||||
Induction System | Naturally Aspirated | Tubo | Tubo | Tubo | Tubocharged & air intercooled | ||||
Governor Type | GAC electronic governor | ||||||||
Governing | <=1% | <=1% | <=1% | <=1% |
Standard supply:
1) Powered by heavy duty industrial diesel engines, famous engine brand can be chosen.
2) Brushless alternator,single bearing,flange connection,IP23,H insulation class,with AVR.
3) Auto control panel with LCD display.
4) Engine mounted battery-charging alternator,Genset with battery charge of main supply.
5) Circuit Breaker,Exhaust Silencer.
6) Copper Radiator for 40°C ambient temperature and double-deck cooling,with fan guard and front guard.
7) Anti-vibration pads fixed between engine/alternator and base frame to ensure the compete genset running stable.
8) Skid-mounted bottom 8 hours fuel tank.
9) Extemal recessed emergency stop button for extra safety.
10)Optional:Soundproof,ATS(automatic transfer switch),AMF panel,Trailer,Parallel system.
Optional:
--Automatic Transfer Switch
--Soundproof Canopy
--Under base tank
--Oil filter
AMF Control Panel- ComAp AMF20 Or DSE7320
Brand | Deepsea/ComAp |
The control module gives digital readouts of: Generator voltage; Output frequency; Engine speed; Battery voltage; Engine hours run. The control module has indicators for failure information: Overspeed/underspeed, Emergency stop Low oil pressure; High water temperature Failure to start Battery charger failure Automatic shutdown occurs under: Low engine oil pressure; High engine water temperature; Overspeed/underspeed; Failure to start after three attempts. | ![]() |
OUR WORKSHOP:

A processing center, the most advance laser machine, CNC lathes , milling machines, grinding machines, etc. , following a precision machining parts, the machine with advanced processing equipment and testing equipment.

Quality Inspection:
the test items before delivery are mainly as follows:
1) Professional 8 Hours test on 25%, 50%,75%, 100%, 110% load before delivery.
2) The noise level is tested. We used good muffer and design and foam to reduce the noise.
3) All of the meters on the control panel shall be tested.
4) The appearance of the genset and all of the label and nameplate shall be checked.

Warranty
12 months or 1000 running hours from shipment date.If the quality problem arise during the warranty period, and verified the problem is caused by our genset-body instead of external or natural reasons.we will supply the relevant spare parts free of charge for maintenance;After the warranty period, we can supply the required spare parts for you under cost prices.